An impression was taken with a metal strip and silicone-based mat

An impression was taken with a metal strip and silicone-based materials. In the laboratory, a stone die was generated from the impression, and a custom-made cast dowel with ball attachment was constructed. It was then cemented with glass ionomer cement and connected to the denture with the direct method. The alternative procedure described in this clinical report was successful for the removal of the fractured abutment screw and use of the existing denture. “
“Purpose: To evaluate the effect of airborne-particle abrasion and mechanico-thermal cycling on the flexural strength Gefitinib solubility dmso of a ceramic fused to cobalt–chromium

alloy or gold alloy. Materials and Methods: Metallic bars (n = 120) were made (25 www.selleckchem.com/products/gsk1120212-jtp-74057.html mm × 3 mm × 0.5 mm): 60 with gold alloy and 60 with Co–Cr. At the central area of the bars (8 mm × 3 mm), a layer of opaque ceramic and then two layers of glass ceramic (Vita VM13, Vita Zahnfabrick) were fired onto it (thickness: 1 mm). Ten specimens from each alloy group were randomly allocated to a surface treatment [(tungsten bur or air-particle abrasion (APA) with Al2O3 at 10 mm or 20 mm

away)] and mechanico-thermal cycling (no cycling or mechanically loaded 20,000 cycles; 10 N distilled water at 37°C and then thermocycled 3000 cycles; 5°C to 55°C, dwell time 30 seconds) combination. Those specimens that did not undergo mechanico-thermal cycling were stored in water (37°C) for 24 hours. Bond strength was measured using a selleck compound three-point bend test, according to ISO 9693. After the flexural strength test, failure types were noted. The data were analyzed using three factor-ANOVA and Tukey’s test (α= 0.05). Results: There were no significant differences between the flexural bond strength of gold and Co–Cr groups (42.64 ± 8.25 and 43.39 ± 10.89 MPa, respectively). APA 10 and 20 mm away surface treatment (45.86 ± 9.31 and 46.38 ± 8.89 MPa, respectively) had similar mean flexural strength values, and both had significantly higher bond strength than tungsten bur treatment (36.81 ± 7.60 MPa). Mechanico-thermal cycling decreased the mean flexural strength values significantly for all six alloy-surface treatment

combinations tested when compared to the control groups. The failure type was adhesive in the metal/ceramic interface for specimens surface treated only with the tungsten bur, and mixed for specimens surface treated with APA 10 and 20 mm. Conclusions: Considering the levels adopted in this study, the alloy did not affect the bond strength; APA with Al2O3 at 10 and 20 mm improved the flexural bond strength between ceramics and alloys used, and the mechanico-thermal cycling of metal-ceramic specimens resulted in a decrease of bond strength. “
“The purpose of this study was to evaluate the impact of occlusal relief of dies on internal adaptation of metal-ceramic casting copings. Standardized preparations were made on 80 extracted third molar teeth.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>